RADIATION MONITOR AT1117M

Portable combined high-sensitive accurate instrument to measure ambient x-ray, gamma and neutron radiation dose equivalent and dose equivalent rate, alpha and beta radiation flus density from contaminated surfaces and alpha and beta radiation surface acitivity and neutron radiation flux density


Features

- Multifunctionality
- High sensitivity and wide measuring ranges Download a leaflet (274 kb)
- Fast response to radiation field change Download Acrobat Reader
- Alpha, beta, gamma, x-ray and neuton radiation source search
- Smart probes (RS232)
- Built-in LED stabilization system
- Audible and visual alarm at dose, dose rate and flux density threshold exceeding
- Field operation in a wide temperature range
- Large backlit LCD
- Logging and transfer to PC up to 100 measurement results
- Two alternative processing units: PU1 and PU2


Application

- Radioecology
- Health services
- Radiation medicine
- Nuclear industry
- Fire service
- Emergency
- Civil defense
- Scientific research
- Customs
- Customs x-ray equipmentr
- Radiography


The radiation monitor AT1117M is a multifunctional portable instrument with digital readout consisting of the processing unit (PU1 and/or PU2) with an internal Geiger-Muller counter and external smart probes BDPA-01, BDPB-01, BDPS-02, BDKN-01, BDKN-03, BDKR-01, BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-09 and BDKG-17. The smart probes BDKG-01, BDKG-03, BDKG-05 and BDKG-17 can be placed in a hermetic container for submerging.


Specification


X-ray and gamma radiation ambient dose equivalent rate measuring range
PU1, PU2 (G-M counter) 10 µSv/h - 100 mSv/h
BDPS-02 (G-M counter) 0.1 µSv/h - 30 mSv/h
BDKR-01 (NaI(Tl), ø9x2 mm) 0.05 - 100 µSv/h
BDKG-01 (G-M counter) 0.1 µSv/h - 10 Sv/h
BDKG-03 (NaI(Tl), ø25x40 mm) 0.03 - 300 µSv/h
BDKG-04 (scintillation plastic, ø30x15 mm) 0.05 µSv/h - 10 Sv/h
BDKG-05 (NaI(Tl), ø40x40 mm) 0.03 - 100 µSv/h
BDKG-09 (G-M counter) 0.1 µSv/h - 5 Sv/h
BDKG-17 (G-M counter) 1 mSv/h - 100 Sv/h
X-ray and gamma radiation ambient dose equivalent measuring range
PU1, PU2 10 µSv - 10 Sv
BDPS-02 0.1 µSv - 1 Sv
BDKR-01 0.05 µSv - 5 mSv
BDKG-01, BDKG-09 0.1 µSv - 10 Sv
BDKG-03 0.03 µSv - 1 Sv
BDKG-04 0.05 µSv - 10 Sv
BDKG-05 0.03 µSv - 0.3 mSv
BDKG-17 1 µSv - 100 Sv
Flux density measuring range
Alpha radiation from contaminated surfaces
BDPA-01 0.1 - 105 part./(min·cm2)
BDPS-02 5 - 106 part./(min·cm2)
Beta radiation from contaminated surfaces
BDPB-01 1 - 5·105 part./(min·cm2)
BDPS-02 6 - 106 part./(min·cm2)
Neutron radiation ambient dose equivalent rate measuring range
BDKN-01 (Pu-Be sources) 0.1 µSv/h - 10 mSv/h
BDKN-03 (0.025 eV - 14 MeV) 0.1 µSv/h - 10 mSv/h
Neutron radiation ambient dose equivalent measuring range
BDKN-01 (Pu-Be sources) 0.1 µSv - 10 Sv
BDKN-03 (0.025 eV - 14 MeV) 0.1 µSv - 10 Sv
Neutron radiation flux density measuring range
BDKN-01, BDKN-03 0.1 - 104 neutron/(s·cm2)
Energy range of detecting x-ray and gamma radiation
BDKR-01 5 - 160 keV
PU1, PU2, BDKG-01, BDKG-09, BDKG-17 60 keV - 3 MeV
BDPS-02, BDKG-04 20 keV - 3 MeV
BDKG-01, BDKG-09 60 keV - 3 MeV
BDKG-03, BDKG-05 50 keV - 3 MeV
Energy range of detecting alpha radiation
BDPS-02 4 - 7 MeV
BDPA-01 3 - 7 MeV
Energy range of detecting beta radiation
BDPS-02, BDPB-01 155 keV - 3.5 MeV
Energy range of detecting neutron radiation
BDKN-01, BDKN-03 0.025 eV - 14 MeV
Intrinsic measurement error
dose rate not more than ± 20 %
flux density not more than ± 20 %
Sensitivity on 137Cs
PU1, PU2 0.3 cps/µSv·h-1
BDPS-02 6.6 cps/µSv·h-1
BDKG-01 4.0 cps/µSv·h-1
BDKG-03 350 cps/µSv·h-1
BDKG-04 100 cps/µSv·h-1
BDKG-05 900 cps/µSv·h-1
BDKG-17 0.004 cps/µSv·h-1
Energy sensitivity response
respect to 137Cs not more than +35 % ÷ -25 %
respect to 90Sr+90Y not more than ± 50 %
Operating temperature range - 30 - + 50°?
Relative air humudity at 35°? up to 95 %
Protection class IP64
Power requirements
internal Ni-MH accumulator unit 6 V
AC mains, 50 Hz 220 V
DC supply 12 V
Continuous operation time
AC mains or DC supply not less than 24 h
fully charged accumulator unit not less than 24 h
Radio disturbance
CEI/IEC CISPR 22:1997
Electromagnetic compatibility
CEI/IEC 61000-4-2:1995
IEC 61000-4-3:1995
Weight
PU1 1.1 kg
PU2, BDPA-01, BDPB-01, BDKR-01, BDKG-04, BDKG-09 0.5 kg
BDPS-02, BDKG-17 0.3 kg
BDKN-01 2.5 kg
BDKN-03 7 kg
BDKG-01 0.42 kg
BDKG-03 0.6 kg
BDKG-04 0.5 kg
BDKG-05 1.2 kg
Dimensions
PU1 177?85?124 mm
PU2 92?62?52 mm
BDPS-02 138x86?60 mm
BDPA-01, BDPB-01 ø80?196 mm
BDKN-01 ø90?290 mm
BDKN-03 ø220?312 mm
BDKR-01, BDKG-01, BDKG-09 ø54?255 mm
BDKG-03 ø 60?295 mm
BDKG-04 ø 60?200 mm
BDKG-05 ø 60?320 mm
BDKG-17 ø 51?167 mm





Complete set: processing unit PU1 or/and PU2, smart probes (the number is on custoner's order), AC adapter, shoulder strap, waist belt, Manual and packing case.

The set of cables and applied software to connect PU to PC, telescopic bar 1.6 m or 3.1 m with internal cable, head-phones, kit of accessories to connect smart probes to PC and applied software are options and they are supplied on additional order.

The radiation monitor AT1117M has pattern approval certificates of Republic of Belarus, Russian Federation, Kazakhstan and Ukraine.

It complies with IEC 60846, IEC 60325 and IEC 61005 International standard requirements.