<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-7963506583475904280</id><updated>2011-06-06T22:32:32.124-07:00</updated><title type='text'>Keshav Koirala</title><subtitle type='html'>http://keshuvko.wordpress.com</subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://keshavko.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://keshavko.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>Me</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>3</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-7963506583475904280.post-3452605764602767091</id><published>2007-07-03T20:58:00.000-07:00</published><updated>2007-07-03T21:01:00.836-07:00</updated><title type='text'>Dosimter blue</title><content type='html'>I need dosimeter; it's been months I have been waiting for it..... But the people at the organisation where the instrument is are being indifferent. :(&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/7963506583475904280-3452605764602767091?l=keshavko.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://keshavko.blogspot.com/feeds/3452605764602767091/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=7963506583475904280&amp;postID=3452605764602767091' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default/3452605764602767091'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default/3452605764602767091'/><link rel='alternate' type='text/html' href='http://keshavko.blogspot.com/2007/07/dosimter-blue.html' title='Dosimter blue'/><author><name>Me</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7963506583475904280.post-6475534047592700794</id><published>2007-06-26T11:16:00.001-07:00</published><updated>2007-06-26T11:17:25.664-07:00</updated><title type='text'>Dosimeter</title><content type='html'>RADIATION MONITOR AT1117M  &lt;br /&gt;&lt;br /&gt; Portable combined high-sensitive accurate instrument to measure ambient x-ray, gamma and neutron radiation dose equivalent and dose equivalent rate, alpha and beta radiation flus density from contaminated surfaces and alpha and beta radiation surface acitivity and neutron radiation flux density &lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Features&lt;br /&gt;&lt;br /&gt;- Multifunctionality  &lt;br /&gt;- High sensitivity and wide measuring ranges  Download a leaflet (274 kb) &lt;br /&gt;- Fast response to radiation field change  Download Acrobat Reader &lt;br /&gt;- Alpha, beta, gamma, x-ray and neuton radiation source search  &lt;br /&gt;- Smart probes (RS232)  &lt;br /&gt;- Built-in LED stabilization system  &lt;br /&gt;- Audible and visual alarm at dose, dose rate and flux density threshold exceeding  &lt;br /&gt;- Field operation in a wide temperature range  &lt;br /&gt;- Large backlit LCD  &lt;br /&gt;- Logging and transfer to PC up to 100 measurement results  &lt;br /&gt;- Two alternative processing units: PU1 and PU2  &lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Application&lt;br /&gt;&lt;br /&gt;- Radioecology &lt;br /&gt;- Health services &lt;br /&gt;- Radiation medicine &lt;br /&gt;- Nuclear industry &lt;br /&gt;- Fire service &lt;br /&gt;- Emergency &lt;br /&gt;- Civil defense &lt;br /&gt;- Scientific research &lt;br /&gt;- Customs &lt;br /&gt;- Customs x-ray equipmentr &lt;br /&gt;- Radiography &lt;br /&gt;&lt;br /&gt;&lt;br /&gt;The radiation monitor AT1117M is a multifunctional portable instrument with digital readout consisting of the processing unit (PU1 and/or PU2) with an internal Geiger-Muller counter and external smart probes BDPA-01, BDPB-01, BDPS-02, BDKN-01, BDKN-03, BDKR-01, BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-09 and BDKG-17. The smart probes BDKG-01, BDKG-03, BDKG-05 and BDKG-17 can be placed in a hermetic container for submerging. &lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Specification&lt;br /&gt; &lt;br /&gt;  &lt;br /&gt;X-ray and gamma radiation ambient dose equivalent rate measuring range   &lt;br /&gt;PU1, PU2 (G-M counter) 10 µSv/h - 100 mSv/h  &lt;br /&gt;BDPS-02 (G-M counter) 0.1 µSv/h - 30 mSv/h &lt;br /&gt;BDKR-01 (NaI(Tl), ø9x2 mm) 0.05 - 100 µSv/h &lt;br /&gt;BDKG-01 (G-M counter) 0.1 µSv/h - 10 Sv/h &lt;br /&gt;BDKG-03 (NaI(Tl), ø25x40 mm) 0.03 - 300 µSv/h &lt;br /&gt;BDKG-04 (scintillation plastic, ø30x15 mm) 0.05 µSv/h - 10 Sv/h &lt;br /&gt;BDKG-05 (NaI(Tl), ø40x40 mm) 0.03 - 100 µSv/h &lt;br /&gt;BDKG-09 (G-M counter) 0.1 µSv/h - 5 Sv/h &lt;br /&gt;BDKG-17 (G-M counter) 1 mSv/h - 100 Sv/h &lt;br /&gt;X-ray and gamma radiation ambient dose equivalent measuring range   &lt;br /&gt;PU1, PU2 10 µSv - 10 Sv &lt;br /&gt;BDPS-02 0.1 µSv - 1 Sv &lt;br /&gt;BDKR-01 0.05 µSv - 5 mSv &lt;br /&gt;BDKG-01, BDKG-09 0.1 µSv - 10 Sv &lt;br /&gt;BDKG-03 0.03 µSv - 1 Sv &lt;br /&gt;BDKG-04 0.05 µSv - 10 Sv &lt;br /&gt;BDKG-05 0.03 µSv - 0.3 mSv &lt;br /&gt;BDKG-17 1 µSv - 100 Sv &lt;br /&gt;Flux density measuring range   &lt;br /&gt;Alpha radiation from contaminated surfaces   &lt;br /&gt;BDPA-01 0.1 - 105 part./(min·cm2) &lt;br /&gt;BDPS-02 5 - 106 part./(min·cm2) &lt;br /&gt;Beta radiation from contaminated surfaces   &lt;br /&gt;BDPB-01 1 - 5·105 part./(min·cm2) &lt;br /&gt;BDPS-02 6 - 106 part./(min·cm2) &lt;br /&gt;Neutron radiation ambient dose equivalent rate measuring range   &lt;br /&gt;BDKN-01 (Pu-Be sources) 0.1 µSv/h - 10 mSv/h &lt;br /&gt;BDKN-03 (0.025 eV - 14 MeV) 0.1 µSv/h - 10 mSv/h &lt;br /&gt;Neutron radiation ambient dose equivalent measuring range   &lt;br /&gt;BDKN-01 (Pu-Be sources) 0.1 µSv - 10 Sv &lt;br /&gt;BDKN-03 (0.025 eV - 14 MeV) 0.1 µSv - 10 Sv &lt;br /&gt;Neutron radiation flux density measuring range   &lt;br /&gt;BDKN-01, BDKN-03 0.1 - 104 neutron/(s·cm2) &lt;br /&gt;Energy range of detecting x-ray and gamma radiation    &lt;br /&gt;BDKR-01 5 - 160 keV &lt;br /&gt;PU1, PU2, BDKG-01, BDKG-09, BDKG-17 60 keV - 3 MeV &lt;br /&gt;BDPS-02, BDKG-04 20 keV - 3 MeV &lt;br /&gt;BDKG-01, BDKG-09 60 keV - 3 MeV &lt;br /&gt;BDKG-03, BDKG-05 50 keV - 3 MeV &lt;br /&gt;Energy range of detecting alpha radiation   &lt;br /&gt;BDPS-02 4 - 7 MeV &lt;br /&gt;BDPA-01 3 - 7 MeV &lt;br /&gt;Energy range of detecting beta radiation   &lt;br /&gt;BDPS-02, BDPB-01 155 keV - 3.5 MeV &lt;br /&gt;Energy range of detecting neutron radiation   &lt;br /&gt;BDKN-01, BDKN-03 0.025 eV - 14 MeV &lt;br /&gt;Intrinsic measurement error   &lt;br /&gt;dose rate not more than ± 20 % &lt;br /&gt;flux density not more than ± 20 %  &lt;br /&gt;Sensitivity on 137Cs   &lt;br /&gt;PU1, PU2 0.3 cps/µSv·h-1 &lt;br /&gt;BDPS-02 6.6 cps/µSv·h-1 &lt;br /&gt;BDKG-01 4.0 cps/µSv·h-1 &lt;br /&gt;BDKG-03 350 cps/µSv·h-1 &lt;br /&gt;BDKG-04 100 cps/µSv·h-1 &lt;br /&gt;BDKG-05 900 cps/µSv·h-1 &lt;br /&gt;BDKG-17 0.004 cps/µSv·h-1 &lt;br /&gt;Energy sensitivity response   &lt;br /&gt;respect to 137Cs not more than +35 % ÷ -25 % &lt;br /&gt;respect to 90Sr+90Y not more than ± 50 % &lt;br /&gt;Operating temperature range - 30 - + 50°? &lt;br /&gt;Relative air humudity at 35°? up to 95 % &lt;br /&gt;Protection class IP64 &lt;br /&gt;Power requirements   &lt;br /&gt;internal Ni-MH accumulator unit 6 V &lt;br /&gt;AC mains, 50 Hz 220 V &lt;br /&gt;DC supply 12 V &lt;br /&gt;Continuous operation time   &lt;br /&gt;AC mains or DC supply not less than 24 h &lt;br /&gt;fully charged accumulator unit not less than 24 h &lt;br /&gt;Radio disturbance&lt;br /&gt;CEI/IEC CISPR 22:1997   &lt;br /&gt;Electromagnetic compatibility&lt;br /&gt;CEI/IEC 61000-4-2:1995&lt;br /&gt;IEC 61000-4-3:1995   &lt;br /&gt;Weight   &lt;br /&gt;PU1 1.1 kg &lt;br /&gt;PU2, BDPA-01, BDPB-01, BDKR-01, BDKG-04, BDKG-09 0.5 kg &lt;br /&gt;BDPS-02, BDKG-17 0.3 kg &lt;br /&gt;BDKN-01 2.5 kg &lt;br /&gt;BDKN-03 7 kg &lt;br /&gt;BDKG-01 0.42 kg &lt;br /&gt;BDKG-03 0.6 kg &lt;br /&gt;BDKG-04 0.5 kg &lt;br /&gt;BDKG-05 1.2 kg &lt;br /&gt;Dimensions  &lt;br /&gt;PU1 177?85?124 mm &lt;br /&gt;PU2 92?62?52 mm &lt;br /&gt;BDPS-02 138x86?60 mm &lt;br /&gt;BDPA-01, BDPB-01 ø80?196 mm &lt;br /&gt;BDKN-01 ø90?290 mm &lt;br /&gt;BDKN-03 ø220?312 mm &lt;br /&gt;BDKR-01, BDKG-01, BDKG-09 ø54?255 mm &lt;br /&gt;BDKG-03 ø 60?295 mm &lt;br /&gt;BDKG-04 ø 60?200 mm &lt;br /&gt;BDKG-05 ø 60?320 mm &lt;br /&gt;BDKG-17 ø 51?167 mm &lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;Complete set: processing unit PU1 or/and PU2, smart probes (the number is on custoner's order), AC adapter, shoulder strap, waist belt, Manual and packing case. &lt;br /&gt;&lt;br /&gt;The set of cables and applied software to connect PU to PC, telescopic bar 1.6 m or 3.1 m with internal cable, head-phones, kit of accessories to connect smart probes to PC and applied software are options and they are supplied on additional order.&lt;br /&gt;&lt;br /&gt;The radiation monitor AT1117M has pattern approval certificates of Republic of Belarus, Russian Federation, Kazakhstan and Ukraine.&lt;br /&gt;&lt;br /&gt;It complies with IEC 60846, IEC 60325 and IEC 61005 International standard requirements.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/7963506583475904280-6475534047592700794?l=keshavko.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://keshavko.blogspot.com/feeds/6475534047592700794/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=7963506583475904280&amp;postID=6475534047592700794' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default/6475534047592700794'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default/6475534047592700794'/><link rel='alternate' type='text/html' href='http://keshavko.blogspot.com/2007/06/dosimeter.html' title='Dosimeter'/><author><name>Me</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-7963506583475904280.post-5372396465780736707</id><published>2007-06-26T11:07:00.001-07:00</published><updated>2007-06-26T11:07:47.200-07:00</updated><title type='text'>Tired</title><content type='html'>I am totally lost&lt;br /&gt;Sky!&lt;br /&gt;Take me up in arms of thy&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/7963506583475904280-5372396465780736707?l=keshavko.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://keshavko.blogspot.com/feeds/5372396465780736707/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=7963506583475904280&amp;postID=5372396465780736707' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default/5372396465780736707'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/7963506583475904280/posts/default/5372396465780736707'/><link rel='alternate' type='text/html' href='http://keshavko.blogspot.com/2007/06/tired.html' title='Tired'/><author><name>Me</name><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><thr:total>0</thr:total></entry></feed>
